| SKU | VA-SLC-4G-V1 |
|---|---|
| Communication | 4G SIM-based with MQTT |
| Model | VA-SLC-4G-V1 |
| Front panel | LCD showing R/Y/B voltage, current and timer status |
| Telemetry | Immediate on light ON/OFF, fault trip and clearance, power restore and schedule activation |
| Remote control | Force ON, Force OFF, return to auto, timed override |
| Group control | Street, zone, ward or feeder groups; each unit individually addressable |
| Configuration readback | Schedules, protection limits, calibration, control mode, firmware version, counters |
| Firmware update | Signed FOTA over 4G with validation and automatic rollback |
| Offline operation | Schedules and protection continue without network; events buffered and uploaded later |
| Web application | Highly customisable dashboard for monitoring, control, groups and reports |
| Mobile app | Monitor and control lights from your phone |
| Astronomical | ON at sunset, OFF at sunrise from configured latitude and longitude |
| RTC windows | Multiple daily windows, cross-midnight (e.g. 18:00–06:00), separate weekday schedules |
| Lux sensor | Optional; ON/OFF thresholds with hysteresis; RTC schedule as backup |
| After power failure | Resumes automatically inside an active window |
| Measurements | Per-phase R/Y/B voltage and current |
| Energy | Apparent power (kVA) and apparent energy (kVAh) |
| Statistics | Burning hours (daily, weekly, monthly), switching cycles, per-phase load distribution |
| Under-voltage | Trip 140 V, reset 150 V |
| Over-voltage | Trip 280 V, reset 270 V |
| Current limits | Low 1 A, high 10 A by default; adjustable to the installed load |
| Phase loss | Detects and identifies missing R, Y or B phase |
| Restart | Automatic scheduled restart once voltage is healthy |
| Contactor | Feedback input detects ON-but-dark, OFF-but-on and welded or failed contactor |
| Lamp failure | Learns normal current; detects partial lamp-bank failure; configurable minimum load %; reports phase or feeder |
| Events | Power fail/restore, low/high voltage, phase loss, over/low current, contactor failure, lamp-bank failure, RTC failure, MQTT offline/online, tamper |
| Tamper | Door-open input; optional vibration/tilt detection; timestamped alert |
| Maintenance mode | Suspends automatic switching for a set period; logs technician actions |
| Asset data | Pole number, feeder and zone, latitude/longitude, installation date, rated load, maintenance notes |
| Diagnostics | RTC validity, network and MQTT status, signal strength, SIM registration, watchdog resets, MQTT reconnects, flash-save status, internal supply |
| Enclosure | Metallic, wall-mount, cable glands |
| Supply | Works on both 230 V AC single-phase and 415 V AC three-phase (4-wire) |
| Operating range | 150–270 V per phase (trips below 140 V, above 280 V) |
| Contactor | 30 A, 440 V |
| Warranty | 1 year |
| Maximum load | 5 kW |
| MPN | VA-SLC-4G-V1 |
| Brand | Vidani Automations |
| Categories | Smart Infrastructure & Access Control, Home Automation, Industrial Applications, IoT Products |